MBRCentral.com is your source of information for OVIVO® MBR products & services. Constantly evolving, MBRCentral.com will provide you with all the tools you need regarding OVIVO® MBR.
Search
  • HOME
  • CASE STUDIES
    • Featured Case Studies
  • SOLUTIONS
    • Ovivo®MBR
    • microBLOX®
    • EQuiptech™
    • stormBLOX™
  • DOWNLOADS
    • QUICK CARDS
    • VIDEOS
    • RESOURCE CENTER
  • ABOUT US
  • SUPPORT
  • CONTACT
  • LOGIN
  • CLIENT’S ZONE
    • LOGOUT
  • Sign In
  • CLIENT’S ZONE
    • LOGIN
    • LOGOUT
MBRCentral.com is your source of information for OVIVO® MBR products & services. Constantly evolving, MBRCentral.com will provide you with all the tools you need regarding OVIVO® MBR.
  • HOME
  • CASE STUDIES
  • SOLUTIONS
    • Ovivo® MBR
    • microBLOX®
    • equipTECH®
    • stormBLOX™
  • DOWNLOADS
    • Quick Cards
    • Videos
    • Resource Center
  • ABOUT US
  • SUPPORT
  • CONTACT
Menu

Return to previous page
Home Case Study

Jerome

Jerome

PROJECT HIGHLIGHTS

Commissioned January, 2008 Domestic WW, CAS Retrofit Permit(s); Discharge 10/1/2   (TN/TP/Turbidity) Municipal ⇒ River MMF Capacity: 3.24 MGD $2.93/gal 9 FTE (Full‐Time Employees)
The  Facility utilizes a state of the art  process to treat waste  to be nearly clean enough for household use.

DESCRIPTION

In 2005, the Jerome Wastewater Treatment Plant was nearing design capacity with a flow of 2 million gallons per day. Ovivo's MBR replaces the existing activated sludge, extended aeration process, which offered very limited biological nutrient removal. Ovivo was able to provide a complete MBR system providing a significant cost savings to the city, all while producing superior quality effluent, allowing the city the opportunity to fall way below its allowed BOD, TSS, Phosphorus and Total nitrogen levels.  Ovivo offered an advanced approach to the large plant application by reducing the number of parts and thus the number of possible failure points, allowing for future expansion, and providing the simplest most reliable MBR product available.

LOCATION

Jerome, ID

IMAGES

GENERATE PDF VERSION

PROJECT OVERVIEW

System Type(s) Enviroquip ® MBR
Previous Facility Type Extended Aeration
Owner City of Jerome
Engineer Aqua Engineering
Contractor Allstate Construction
Operations City of Jerome
Delivery Method Pre-Selection
Time To Retrofit 18 months
Total Installed Project Cost $9,500,000

PLANT DESIGN INFORMATION

Fine Screen Type Band Screen
Aperture or Slot Size 3 mm
Supplemental Aeration Technology Fine Bubble, Tubes
MBR Blower Type Positive Displacement
Solids Management Data Aerobic Digestion
SCADA System Wonderware
Disinfection Method UV
# Process Stages 3

MBR (MEMBRANE ZONE) DESIGN

Filtration Mode Pumped
# of Reactors : 6
Submerged Membrane Unit (SMU) RW400, KUBOTA®
# SMU 40
Design Flux (MMF) 15.5 gfd
Minimum Temperature 14°C
Peak Factor 2.0
# of Maintenance Cleans 4
Jamestown S’Klallum
Kent Manor